nVent RAYCHEM ETL self-regulating trace heating cable
详情介绍
概述
Trace heating cable for pipe frost protection
RAYCHEM self-regulating heating cable for frost protection of pipes.
The ETL trace heating cable provides energy-efficient and easy-to-use protection against frozen pipes.
In or on water pipes installation:
- R-ETL-A (10 W/m @ 5°C)
- R-ETL-B (16 W/m @ 5°C)
On water pipes installation only:
- R-ETL-A-CR (10 W/m @ 5°C)
- R-ETL-B-CR (16 W/m @ 5°C)
- Easy to design and install with cut-to-length capability, cable metre marking and simple heat shrink components
- Small geometry for ease of installation
- Safe: no overheating possible: even when crossed or closely spaced
- Energy-efficiency through self-regulating technology
- Maintenance-free: no moving parts
Further energy savings can be made with various control and monitoring systems.
技术规格
Product | R-ETL-A | R-ETL-B | R-ETL-A-CR | R-ETL-B-CR |
Power output @ 5°C | 10 | 16 | 10 | 16 |
Supply Voltage | 230 Vac | 230 Vac | 230 Vac | 230 Vac |
Maximum Exposure temperature (Heater power off) Max. 800 Hours Exposure. | 65°C | 65°C | 65°C | 65°C |
Max. maintain temperature. | 40°C | 40°C | 40°C | 40°C |
Dimensions | 8.5mm x 5.8mm | 8.5mm x 5.8mm | 8.5mm x 5.8mm | 8.5mm x 5.8mm |
Electrical Grounding Method (Earthing) | Nickel Plated Copper Braid | Nickel Plated Copper Braid | Nickel Plated Copper Braid | Nickel Plated Copper Braid |
Primary (Inner) Jacket material | Radiation cross-linked modified Polyolefin | Radiation cross-linked modified Polyolefin | Radiation cross-linked modified Polyolefin | Radiation cross-linked modified Polyolefin |
Final (Outer) Jacket Material | Fluoropolymer | Fluoropolymer | Modified Polyolefin | Modified Polyolefin |
Minimum installation temperature | -20°C | -20°C | -20°C | -20°C |
Minimum Bend Radius | 10mm | 10mm | 10mm | 10mm |
Maximum Circuit Length (5°C Switch-on) | 100m (10A) On Pipe | 100m (16A) On Pipe | 100m (10A) On Pipe | 100m (16A) On Pipe |
60m (10A) In Pipe | 60m (16A) In Pipe | Not for in pipe use | Not for in pipe use | |
Certification & Approvals | Test & Approved to IEC62395. | Test & Approved to IEC62395. | Test & Approved to IEC62395. | Test & Approved to IEC62395. |
CE Marked. | CE Marked. | CE Marked. | CE Marked. |
相关文件
数据表
- Raychem ETL Data Sheet (PDF)