| Features Provided | panel seal and shaft seal and switch |
| Terminal Location | radially positioned over less than half the circumference |
| Section Quantity | 2 |
| Electrical Resistance Per Section | 10.0 percent, rated amperes c and better finish |
| Nonturn Device Radius | 0.437 inches nominal |
| Test Data Document | 06481-914105 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing) |
| Maximum Stop Torque | 160.00 inch-ounces |
| Overall Diameter | 2.000 inches maximum |
| Maximum Starting Torque | 8.00 inch-ounces |
| Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power | 105.0 single section |
| Rotary Actuator Travel In Angular Deg | 305.0 nominal |
| Shaft Length | 1.036 inches nominal |
| Body Length | 2.000 inches maximum |
| Actuator Travel Control Feature | stops |
| Body Diameter | 2.000 inches maximum |
| Function Characteristic Per Section | all sections equation |
| Shaft Bearing Type | sleeve |
| Screw Thread Diameter | 0.375 inches nominal |
| Switch Operating Position | end of rotation |
| Shaft Style | round, flatted |
| Mounting Bushing Length | 0.469 inches nominal |
| Unpackaged Unit Weight | 280.0 grams |
| Actuator Type | single shaft |
| Maximum Running Torque | 8.00 inch-ounces |
| Power Dissipation Rating Per Section In Watts | 1.0 free air single section |
| Overall Length | 3.046 inches maximum |
| Switch Type | rotary |
| Shaft Diameter | 0.250 inches nominal |
| Terminal Type And Quantity | 8 turret |
| Mounting Method | standard bushing |
| Nonturn Device Location | at 6 oclock |
| Function Conformity Tolerance Per Section | -0.10/+0.10 single section |
| Switch Current Type And Rating In Amps | 4.000 dc |
| Function Conformity Per Section | all sections absolute conformity |
| Flat Height | 0.220 inches nominal |
| Screw Thread Quantity Per Inch | 32.0 |
| Body Style | cylindrical bushing mounted |
| Resistance Tolerance Per Section In Percent | -2.0/+2.0 all sections |
| Switch Contact Arrangement | single pole, single throw, normally open, both positions maintained |
| Screw Thread Series Designator | unef |
| Ambient Temp In Deg Celsius Per Section At Full Rated Power | 70.0 single section |
| Effective Electrical Rotation In Deg Angular Rotation | 300.0 nominal |
| First Flat Length | 0.487 inches nominal |
| Switch Voltage Rating In Volts | 28.0 |
| Temp Coefficient Of Resistance Per Section In Ppm Per Deg Celsius | -100.0/+100.0 all sections |
| Reliability Indicator | not established |