| Thread Series Designator | uns |
| Thread Quantity Per Inch | 32 |
| Test Data Document | 81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type |
| Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 3500.0 ac single location and 6000.0 dc single location |
| Center To Center Distance Between Terminals Parallel To Length | 0.673 inches minimum and 0.735 inches maximum |
| Reset Method | manual |
| Circuit Protection Type | overcurrent single location |
| Manual Actuator Type And Quantity | 1 push-pull |
| Pole Quantity | 1 |
| Trip Release Ambient Temp Rating | 25.0 deg celsius nominal single location |
| Mounting Facility Type And Quantity | 1 threaded bushing w/panel seal |
| Actuator Function | trip-reset |
| Operating Voltage Type And Rating Per Pole In Volts | 115.0 ac single location and 28.0 dc single location |
| Body Length | 1.094 inches maximum |
| Fragility Factor | moderately rugged |
| Specification/standard Data | 96906-ms25244 government standard |
| Trip Release Method | thermal single location |
| Actuator Position Designation | at pole one |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 138.0 single location |
| Case Material | metal |
| Main Contact Tripping Mechanism Type | trip free |
| Inclosure Protection Type For Which Designed | shock resistant and hermetically sealed and vibration resistant |
| Trip Release Characteristic | time delay single location |
| Unpackaged Unit Weight | 1.813 pounds |
| Frequency In Hertz | 400.0 single location |
| Terminal Type And Quantity | 2 tab w/screw |
| Nominal Thread Size | 0.469 inches |
| Bushing Length | 0.235 inches minimum and 0.265 inches maximum |
| Mounting Surface To Terminal End Distance | 1.840 inches maximum |
| Body Width | 0.750 inches maximum |
| ~1 | data on certain environmental and performance |
| Body Style | single pole type |
| Trip Delay Time In Seconds Per Rated Continuous Current | 15.000 minimum at 200 pct single location and 55.000 maximum at 200 pct single location |
| Maximum Continuous Load Current Rating Per Pole | 25.0 amperes ac single location and 25.0 amperes dc single location |
| Storage Type | general purpose warehouse |
| Internal Trip Release Configuration | series trip single location |