Precious Material | silver |
Thread Series Designator | unc |
Thread Quantity Per Inch | 32 |
Test Data Document | 81205-bacc182l10a drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing) |
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1500.0 ac all locations |
Center To Center Distance Between Terminals Parallel To Length | 1.471 inches minimum and 1.501 inches maximum |
Reset Method | manual |
Pole Quantity | 3 |
Circuit Protection Type | overcurrent all locations |
Manual Actuator Type And Quantity | 1 push-pull |
Trip Release Ambient Temp Rating | 25.0 deg celsius nominal all locations |
Mounting Facility Type And Quantity | 6 threaded hole |
Actuator Function | trip-reset |
Operating Voltage Type And Rating Per Pole In Volts | 200.0 ac all locations |
Body Length | 2.200 inches maximum |
Fragility Factor | moderately rugged |
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.735 inches minimum and 0.751 inches maximum |
Actuator Position Designation | at pole two |
Trip Release Method | thermal all locations |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 all locations |
Main Contact Tripping Mechanism Type | trip free |
Case Material | plastic |
Inclosure Protection Type For Which Designed | general purpose |
Trip Release Characteristic | time delay all locations |
Unpackaged Unit Weight | 0.500 pounds |
Frequency In Hertz | 400.0 all locations |
Nominal Thread Size | 0.138 inches |
Terminal Type And Quantity | 6 screw |
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 1.780 inches minimum and 1.840 inches maximum |
Precious Material And Location | terminal surfaces silver |
Bushing Length | 0.220 inches minimum and 0.280 inches maximum |
Body Width | 2.250 inches maximum |
Center To Center Distance Between Terminals Parallel To Width | 0.735 inches minimum and 0.751 inches maximum |
Body Style | multipole-single actuator type |
Trip Delay Time In Seconds Per Rated Continuous Current | 10.000 minimum at 200 pct all locations and 65.000 maximum at 200 pct all locations |
Body Height | 2.125 inches maximum |
Maximum Continuous Load Current Rating Per Pole | 10.0 amperes ac all locations |
Storage Type | general purpose warehouse |
Internal Trip Release Configuration | series trip all locations |