| Thread Quantity Per Inch | 32 |
| Thread Series Designator | uns |
| Test Data Document | 96906-ms26574 standard (includes industry or association standards, individual manufactureer standards, etc.). |
| Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 800.0 ac single location and 800.0 dc single location |
| Center To Center Distance Between Terminals Parallel To Length | 0.593 inches nominal |
| Reset Method | manual |
| Circuit Protection Type | overcurrent single location |
| Manual Actuator Type And Quantity | 1 push-pull |
| Pole Quantity | 1 |
| Mounting Facility Type And Quantity | 1 threaded bushing |
| Actuator Function | reset |
| Operating Voltage Type And Rating Per Pole In Volts | 200.0 ac single location and 28.0 dc single location |
| Body Length | 0.780 inches maximum |
| Fragility Factor | moderately rugged |
| Actuator Position Designation | at pole one |
| Trip Release Method | magnetic-hydraulic single location |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 single location |
| Main Contact Tripping Mechanism Type | trip free |
| Case Material | plastic |
| Inclosure Protection Type For Which Designed | explosion proof |
| Trip Release Characteristic | time delay single location |
| Frequency In Hertz | 400.0 single location |
| Terminal Type And Quantity | 2 screw |
| Nominal Thread Size | 0.437 inches |
| Bushing Length | 0.359 inches nominal |
| Mounting Surface To Terminal End Distance | 1.420 inches maximum |
| Body Width | 0.580 inches maximum |
| Special Handling Feature | magnetic |
| Body Style | single pole type |
| Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location |
| Maximum Continuous Load Current Rating Per Pole | 2.0 amperes ac single location and 2.0 amperes dc single location |
| Internal Trip Release Configuration | series trip single location |