| Thread Series Designator | unc |
| Thread Quantity Per Inch | 32 |
| Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1600.0 ac single location |
| Center To Center Distance Between Terminals Parallel To Length | 0.812 inches nominal |
| Reset Method | manual |
| Manual Actuator Type And Quantity | 1 push button |
| Circuit Protection Type | overcurrent single location |
| Pole Quantity | 1 |
| Trip Release Ambient Temp Rating | 25.0 deg celsius nominal single location |
| Mounting Facility Type And Quantity | 1 threaded bushing |
| Actuator Function | reset |
| Operating Voltage Type And Rating Per Pole In Volts | 115.0 ac single location |
| Body Length | 1.094 inches maximum |
| Fragility Factor | moderately rugged |
| Actuator Position Designation | at pole one |
| Trip Release Method | thermal single location |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 120.0 single location |
| Case Material | plastic |
| Main Contact Tripping Mechanism Type | trip free |
| Ultimate Trip Time Per Pole In Seconds | 1800.000 nominal single location |
| Inclosure Protection Type For Which Designed | corrosion resistant |
| Trip Release Characteristic | time delay single location |
| Frequency In Hertz | 60.0 single location |
| Nominal Thread Size | 0.469 inches |
| Terminal Type And Quantity | 2 screw |
| Bushing Length | 0.297 inches nominal |
| Mounting Surface To Terminal End Distance | 1.329 inches nominal |
| Body Width | 0.750 inches maximum |
| Body Style | single pole type |
| Trip Delay Time In Seconds Per Rated Continuous Current | 150.000 minimum at 150 pct single location and 30.000 maximum at 200 pct single location |
| Maximum Continuous Load Current Rating Per Pole | 2.0 amperes ac single location |
| Storage Type | general purpose warehouse |
| Internal Trip Release Configuration | series trip single location |