Thread Quantity Per Inch | 32 |
Thread Series Designator | unef |
Test Data Document | 81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type |
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 ac single location and 1000.0 dc single location |
Center To Center Distance Between Terminals Parallel To Length | 0.906 inches maximum |
Reset Method | manual |
Circuit Protection Type | overcurrent single location |
Pole Quantity | 1 |
Manual Actuator Type And Quantity | 1 toggle |
Mounting Facility Type And Quantity | 1 threaded bushing w/panel seal |
Actuator Function | trip-reset |
Operating Voltage Type And Rating Per Pole In Volts | 240.0 ac single location and 50.0 dc single location |
Body Length | 1.562 inches maximum |
Fragility Factor | moderately rugged |
Thread Pitch Diameters | +0.3503/+0.3537 inches |
Specification/standard Data | 81349-mil-c-39019/1 government specification |
Trip Release Method | magnetic single location |
Actuator Position Designation | at pole one |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 115.0 single location |
Case Material | metal |
Main Contact Tripping Mechanism Type | trip free |
Inclosure Protection Type For Which Designed | hermetically sealed and moisture resistant and fungus resistant and salt spray proof |
Trip Release Characteristic | time delay single location |
Frequency In Hertz | 400.0 single location |
Terminal Type And Quantity | 2 wire hook |
Nominal Thread Size | 0.375 inches |
Bushing Length | 0.332 inches minimum and 0.380 inches maximum |
Mounting Surface To Terminal End Distance | 1.700 inches maximum |
Body Width | 0.625 inches maximum |
Special Handling Feature | magnetic |
~1 | data on certain environmental and performanc |
Body Style | single pole type |
Trip Delay Time In Seconds Per Rated Continuous Current | 0.500 minimum at 200 pct single location and 9.000 maximum at 200 pct single location |
Arc Quenching Method | magnetic blowout |
Maximum Continuous Load Current Rating Per Pole | 10.0 amperes ac single location and 10.0 amperes dc single location |
Storage Type | general purpose warehouse |
Internal Trip Release Configuration | series trip single location |