Thread Series Designator | unc |
Thread Quantity Per Inch | 32 |
Test Data Document | 81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type |
Center To Center Distance Between Terminals Parallel To Length | 1.940 inches nominal |
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 5000.0 dc single location |
Reset Method | manual |
Circuit Protection Type | overcurrent single location |
Pole Quantity | 1 |
Manual Actuator Type And Quantity | 1 toggle |
Mounting Facility Type And Quantity | 2 threaded hole |
Actuator Function | trip-reset |
Operating Voltage Type And Rating Per Pole In Volts | 50.0 dc single location |
Body Length | 2.480 inches minimum and 2.500 inches maximum |
Fragility Factor | moderately rugged |
Specification/standard Data | 81349-mil-c-55629/1 government specification |
Thread Pitch Diameters | +0.1177/+0.1214 inches |
Trip Release Method | magnetic single location |
Actuator Position Designation | at pole one |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 single location |
Main Contact Tripping Mechanism Type | trip free |
Case Material | plastic |
Inclosure Protection Type For Which Designed | shock resistant and moisture resistant and vibration resistant |
Boss Height | 0.150 inches nominal |
Trip Release Characteristic | time delay single location |
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.050 inches minimum and 2.070 inches maximum |
Nominal Thread Size | 0.138 inches |
Terminal Type And Quantity | 2 threaded stud |
Mounting Surface To Terminal End Distance | 2.475 inches nominal |
Body Width | 0.750 inches maximum |
Special Handling Feature | magnetic |
~1 | data on certain environmental and performanc |
Body Style | single pole type |
Trip Delay Time In Seconds Per Rated Continuous Current | 0.150 minimum at 200 pct single location and 1.500 maximum at 200 pct single location |
Arc Quenching Method | magnetic blowout |
Maximum Continuous Load Current Rating Per Pole | 2.0 amperes dc single location |
Storage Type | general purpose warehouse |
Internal Trip Release Configuration | series trip single location |