| Terminal Location | radially positioned over less than half the circumference |
| Features Provided | humidity proof |
| Section Quantity | 2 |
| Electrical Resistance Per Section | 250.0 ohms all sections |
| Iii Overall Length | 3.250 inches maximum |
| Maximum Stop Torque | 80.00 inch-ounces (ounce-inches) |
| Shaft Radial Play | 0.001 inches |
| Shaft End Play | 0.0045 inches |
| Maximum Starting Torque | 6.00 inch-ounces (ounce-inches) |
| Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power | 150.0 all sections |
| Rotary Actuator Travel In Angular Deg | 300.0 nominal |
| Shaft Length | 1.500 inches nominal |
| Body Length | 1.750 inches maximum |
| Body Diameter | 0.625 inches maximum |
| Actuator Travel Control Feature | stops |
| Shaft Bearing Type | sleeve |
| Screw Thread Diameter | 0.375 inches nominal |
| Function Characteristic Per Section | all sections linear |
| Shaft Style | 17c round, stepped |
| Lateral Runout | 0.001 inches |
| Mounting Bushing Length | 0.312 inches nominal |
| Pilot Diameter Runout | 0.0015 inches |
| Actuator Type | dual concentric |
| Maximum Running Torque | 3.00 inch-ounces (ounce-inches) |
| Undercut Diameter | 0.124 inches maximum |
| Power Dissipation Rating Per Section In Watts | 1.5 free air all sections |
| Terminal Type And Quantity | 6 turret |
| Shaft Diameter | 0.249 inches maximum |
| Mounting Method | standard bushing |
| Function Conformity Tolerance Per Section | -0.25 to 0.25 all sections |
| Undercut Length | 0.500 inches nominal |
| Temp Coefficient Of Resistance Wire Per Section In Ppm Per Deg Celsius | -20.0 to 20.0 all sections |
| Screw Thread Quantity Per Inch | 32.0 |
| Function Conformity Per Section | all sections absolute linearity |
| Shaft Runout | 0.001 inches |
| Resistance Tolerance Per Section In Percent | -5.0 to 5.0 all sections |
| Body Style | 1b cylindrical bushing mounted |
| Iii Overall Diameter | 1.000 inches maximum |
| Iii Fragility Factor | moderately rugged |
| Screw Thread Series Designator | unef |
| Ambient Temp In Deg Celsius Per Section At Full Rated Power | 80.0 all sections |
| Effective Electrical Rotation In Deg Angular Rotation | 300.0 nominal |
| Reliability Indicator | not established |