| Thread Series Designator | unc |
| Thread Quantity Per Inch | 32 |
| External Actuator Linkage Arrangement | one and two linked |
| Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 5000.0 dc all locations |
| Center To Center Distance Between Terminals Parallel To Length | 3.053 inches minimum and 3.073 inches maximum |
| Reset Method | manual |
| Manual Actuator Type And Quantity | 2 toggle |
| Circuit Protection Type | overcurrent all locations |
| Pole Quantity | 2 |
| Mounting Facility Type And Quantity | 4 threaded hole |
| Actuator Function | trip-reset |
| Operating Voltage Type And Rating Per Pole In Volts | 30.0 dc all locations |
| Body Length | 3.709 inches minimum and 3.729 inches maximum |
| Fragility Factor | moderately rugged |
| Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 1.021 inches minimum and 1.041 inches maximum |
| Actuator Position Designation | at each pole |
| Trip Release Method | magnetic-hydraulic all locations |
| Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 all locations |
| Main Contact Tripping Mechanism Type | trip free |
| Case Material | plastic |
| Inclosure Protection Type For Which Designed | dustproof and fungus proof |
| Boss Height | 0.146 inches minimum and 0.166 inches maximum |
| Trip Release Characteristic | time delay all locations |
| Terminal Type And Quantity | 4 threaded stud |
| Nominal Thread Size | 0.138 inches |
| Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.740 inches minimum and 2.760 inches maximum |
| Mounting Surface To Terminal End Distance | 3.239 inches nominal |
| Body Width | 2.021 inches minimum and 2.041 inches maximum |
| Center To Center Distance Between Terminals Parallel To Width | 1.021 inches minimum and 1.041 inches maximum |
| Body Style | multipole-multiple actuator type |
| Trip Delay Time In Seconds Per Rated Continuous Current | 2.500 minimum at 200 pct all locations and 8.000 maximum at 200 pct all locations |
| Arc Quenching Method | magnetic blowout |
| Maximum Continuous Load Current Rating Per Pole | 150.0 amperes dc all locations |
| Storage Type | general purpose warehouse |
| Internal Trip Release Configuration | series trip all locations |