Nominal switching capacity (resistive load) | 1 A 30 V DC |
Expected life (min.operations) - Electrical (at 20 cpm) | 1 A 30 V DC resistive - 2�10^5 |
Unit weight | Approx. 2 g .071 oz |
Conditions for operation, transport and storage (Not freezing and condensing at low temperature) - Humidity | 5 to 85% R.H. |
Expected life (min.operations) - Mechanical (at 180 cpm) | 5x10^7 |
Nominal operating current, (�10%) | 2.9 mA |
Initial surge voltage - Between contacts and coil (2�10 ?s) | 2,500 V (Telcordia) |
Vibration resistance - Destructive | 10 to 55 Hz at double amplitude of 5 mm |
Max. switching power (resistive load) | 30 W (DC) |
Conditions for operation, transport and storage (Not freezing and condensing at low temperature) - Ambient temp. | �40°C to +70°C, �40°F to +158°F |
Nominal operating power | 35 mW (1.5 to 12 V DC), 50 mW (24 V DC) |
Operate time [Set time] (at 20�C)(at nominal voltage) | Max. 5 ms (Approx. 3 ms), [Max. 5 ms (Approx. 3 ms)] |
Initial breakdown voltage - Between open contacts | 750 Vrms for 1min. |
[Reset time] (at 20�C)(at nominal voltage) | Max. 5 ms (Approx. 1.5 ms) [Max. 5 ms (Approx. 3 ms)] |
Temperature rise (at 20�C) | Max. 50°C |
Max. switching current | 1 A |
Min. switching capacity | 10 ?A 10 mV DC |
Contact material | Gold-clad silver alloy |
Vibration resistance - Functional | 10 to 55 Hz at double amplitude of 3.3 mm |
Reset voltage, (max.) (initial) | 9.6 VDC |
Max. switching voltage | 110 V DC |
Shock resistance - Destructive | Min. 1,000 m/s^2{100G] |
Set voltage, (max.) (initial) | 9.6 VDC |
Initial surge voltage - Between contacts, 10 �160 ?s | 1,500V (FCC Part 68) |
Mounting | PC Board |
Operating Function | 1 Coil Latching |
Initial insulation resistance | Min. 10,000M ohm (at 500V DC) |
Contact Configuration | 2C DPDT |
Initial breakdown voltage - Between contact sets | 1,000 Vrms for 1min. |
Max. allowable voltage | 18 VDC |
Sub Category | Signal Relay |
Coil Voltage | 12 VDC |
Packaging | Tube packing |
Main Category | Relays |
Coil resistance, (�10%) | 4114 ohm |
Shock resistance - Functional | Min. 750 m/s^2 {75 G} |
Current | 1 Amp |
Initial breakdown voltage - Between contact and coil | 1,800 Vrms for 1min. |
Initial contact resistance, max. (By voltage drop 6 V DC 1A ) | 100 mohm |