Initial breakdown voltage - Between contacts sets | 2,000 Vrms for 1 min. |
Functional Vibration resistance | 10 to 55 Hz at 1 mm double amplitude |
Mechanical Life (at 180 cpm) | AC type: 10^7, DC type: 10^6 |
Unit weight | Approx. 240 g 8.47 oz |
Nominal switching capacity | 20 A 250 V AC (resistive) |
Max. allowable, voltage | 13.2 VAC |
Inductance | 0.05 H |
Pick-up voltage, (max.) | 9.6 VAC |
Humidity | 5 to 85% R.H. |
Initial breakdown voltage - Between open contacts | 2,000 Vrms for 1 min. |
Destructive Shock resistance | 980 m/s^2 {100 G} |
Nominal coil voltage | 12 VAC |
Initial contact resistance, max. (By voltage drop 6 V DC 1A) | 15 mohm |
Min. switching capacity | 100 mA, 5 V DC |
Contact material | Silver alloy |
Functional Shock resistance | 98 m/s^2 {10 G} (except for the contact moving direction) |
Operate time (approx.) (at nominal voltage) - 3 Form C & 4 Form C type | Max. 40 ms |
Release time (without diode) (approx.) (at nominal voltage) - 2 Form C type | Max. 30 ms |
Initial breakdown voltage - Between contacts and coil | 2,000 Vrms for 1 min. |
Ambient temp. | �50�C to +40�C, �58�F to +104�F |
Nominal coil current | 632 mA |
Operating power | (approx.)7.6 W |
Mounting | Plug-In |
Operating Function | Single Side Stable |
Initial insulation resistance | Min. 100 Mohm at 500 V DC |
Destructive Vibration resistance | 10 to 55 Hz at 2 mm double amplitude |
Contact Configuration | 4C 4PDT |
Drop-out voltage, (min.) | 3.6 VAC |
Sub Category | Power Relay |
Coil Voltage | 12 VAC |
Main Category | Relays |
Maximum operating speed | 20 cpm |
Release time (without diode) (approx.) (at nominal voltage) - 3 Form C & 4 Form C type | Max. 40 ms |
Current | 20 Amps |
Operate time (approx.) (at nominal voltage) - 2 Form C type | Max. 30 ms |