Nominal switching capacity (resistive load) | 1 A 30 V DC, 0.3 A 125 V AC |
Expected life (min.operations) - Electrical (at 20 cpm) | 1 A 30 V DC resistive - 10^5, 0.3 A 125 V AC resistive - 10^5 |
Unit weight | Approx. 1 g .035 oz |
Nominal operating current, (±10%) | 46.7 mA |
Temperature rise (at 20°C) | Max. 50°C |
Conditions for operation, transport and storage (Not freezing and condensing at low temperature) - Humidity | 5 to 85% R.H. |
Initial surge voltage - Between contacts and coil (2×10 ?s) | 2,500 V (Telcordia) |
Operate time [Set time] (at 20°C) | Max. 4 ms (Approx. 2 ms), [Max. 4 ms (Approx. 2 ms)] |
Vibration resistance - Destructive | 10 to 55 Hz at double amplitude of 5 mm |
Max. switching power (resistive load) | 30 W, 37.5 V A |
Conditions for operation, transport and storage (Not freezing and condensing at low temperature) - Ambient temp. | 40°C to 85°C, 40°F to 185°F |
Nominal operating power | 140mW (1.5 to 12 V DC), 230mW (24 V DC) |
Initial breakdown voltage - Between open contacts | 750 Vrms for 1min. |
Max. switching current | 1 A |
Coil resistance, (±10%) | 64.2 ohm |
Min. switching capacity | 10 ?A 10 mV DC |
Contact material | Stationary: AgPd+Au clad Movable: AgPd |
Vibration resistance - Functional | 10 to 55 Hz at double amplitude of 3.3 mm |
Drop-out voltage, (min.) (initial) | 0.3 VDC |
Max. switching voltage | 110 V DC, 125 V AC |
Release time (without diode) [Reset time] (at 20°C) | Max. 4 ms (Approx. 1 ms), [Max. 4 ms (Approx. 2 ms)] |
Shock resistance - Destructive | Min. 1,000 m/s^2{100G] |
Expected life (min.operations) - Mechanical (at 750 cpm) | 5 × 10^7 |
Mounting | Surface Mount |
Operating Function | Single Side Stable |
Initial insulation resistance | Min. 10,000M ohm (at 500V DC) |
Contact Configuration | 2C DPDT |
Initial breakdown voltage - Between contact sets | 1,000 Vrms for 1min. |
Pick-up voltage, (max.) (initial) | 2.25 VDC |
Max. allowable voltage | 4.5 VDC |
Sub Category | Signal Relay |
Coil Voltage | 3 VDC |
Packaging | Tape and reel packing |
Main Category | Relays |
Shock resistance - Functional | Min. 750 m/s^2{75G] |
Current | 1 Amp |
Initial breakdown voltage - Between contact and coil | 1,500 Vrms for 1min. |
Initial contact resistance, max. (By voltage drop 6 V DC 1A ) | 100 mohm |
Initial surge voltage - Between open contacts (10×160 ?s) | 1,500 V (FCC Part 68) |