Functional Vibration resistance | 43 m/s^2 {4.4 G} 10 to 200Hz |
Nominal coil current, mA (±10%) (at 20°C) | 0.103 A (at peak) |
Nominal switching capacity (resistive load) | 10A 400V DC |
Unit weight | 150 A 1 Form A: 600 g 21.16oz, 150 A 2 Form A: 1,100 g 38.80oz, 60 A: 340 g 12.00oz, 10 A: 80 g 2.820oz |
Reset time (without diode) (at 20°C) (at nominal voltage) | Max. 30ms |
Expected life (min. operations) - Mechanical | 10^6 |
Short term current | 15A (2min), 30A (30s) |
Nominal operating power | n/a |
Ambient temperature | 40°C to +80°C, 40°F to +176°F |
Humidity | 5 to 85% R.H. |
Initial breakdown voltage - Between open contacts | AC 2,500 Vrms for 1 min |
Destructive Shock resistance | Min. 490 m/s^2 {50 G} |
Reverse cut-off current | 10A 200V DC (Min. 2.5×10^3 cycles) |
Functional Shock resistance | Min. 196 m/s^2 {20 G} |
Overload opening/closing rating | 30A 400V DC (Min. 50 cycles) |
Expected life (min. operations) - Electrical | 7.5×10^4 10A 400V DC (L/R&1ms) |
Mounting | Top Mount |
Operating Function | Single Side Stable |
Contact voltage drop (Max.) | 0.5V (When current [is 10A per 1] contact set) |
Initial insulation resistance | Min. 100 Mohm (at 500 V DC) |
Destructive Vibration resistance | 43 m/s^2 {4.4 G} 10 to 200 Hz |
Contact Configuration | 1A SPST-NO |
Operating power, W (12 V DC, at 20°C) | Approx.1.4W |
Max. cut-off current | n/a |
Max. allowable voltage | 14 VDC |
Sub Category | General Purpose Relay |
Coil Voltage | 12 VDC |
Pick-up voltage, (max.) (at 20°C) | 9 VDC |
Operate time (at 20°C) (at nominal voltage) | Max. 50ms |
Main Category | Relays |
Drop-out voltage, (min.) (at 20°C) | 0.75 VDC |
Current | 10 Amps |
Initial breakdown voltage - Between contact and coil | AC 2,500 Vrms for 1 min. |
Indicator Contact Arrangement | without indicator contact |